Packard EMI30ER1 Embraco 1/12 Horsepower Compressor R12

Special Price $209.02 Regular Price $348.59
In stock
Available Quantity:   7
SKU
EMI30ER1
✓ This Product Replaces: EMI30ER

Product Description

The Packard EMI30ER1 Embraco 1/10HP Compressor 350 BTU Blend/R12 115V/1PH circulates coolant through the system to support the cooling cycle. It works by compressing low-pressure refrigerant vapor and increasing its pressure before directing it toward the condenser for heat release. It is placed within the cooling system compartment and connects to refrigerant tubing, electrical wiring and cooling components. It operates as a central mechanical component by maintaining refrigerant movement between the evaporator and condenser and supports the cooling process by maintaining refrigerant pressure and circulation required for normal cooling system operation.

Manufacturer

Product Overview:

Within the refrigeration system, the compressor provides the mechanical action required to circulate refrigerant through the cooling circuit. The Packard EMI30ER1 Embraco 1/12 Horsepower Compressor R12 is specified for R12 refrigerant applications and has a 1/12 horsepower rating. These specifications identify the compressor's power class and refrigerant application for the applicable refrigeration system.

Refrigerant Compression Function:

The compressor draws low-pressure refrigerant vapor from the evaporator side of the refrigeration circuit and compresses it to a higher pressure. This compression raises the refrigerant's pressure and temperature and prepares the refrigerant for movement into the condenser. The 1/12 horsepower rating identifies the specified power class of the EMI30ER1, while the R12 designation corresponds to its stated refrigerant application.

Refrigeration Cycle Integration:

The compressor operates between the evaporator and condenser stages of the refrigerator's refrigeration circuit. Refrigerant returning from the evaporator enters the compressor, passes through the compression stage, and leaves toward the condenser for the next stage of the cycle. The compressor's continuous pumping action keeps refrigerant moving through the closed refrigeration circuit as the appliance carries out its cooling process.

Replacement Guidelines:

Replacement of the Packard EMI30ER1 Embraco 1/12 Horsepower Compressor R12 can be considered when the compressor no longer provides the compression required to maintain refrigerant movement through the refrigeration circuit. A compressor condition that interrupts the compression cycle can affect the refrigerator's ability to carry out its normal cooling process. Replacing the affected compressor restores the compression component responsible for maintaining refrigerant circulation through the refrigeration system.

Common Failure Symptoms:

  • Refrigerator cooling becomes inadequate or stops
  • The refrigeration cycle does not maintain normal cooling
  • Refrigerant circulation through the cooling circuit is interrupted
  • The compressor does not maintain the compression required for the refrigeration cycle
  • Refrigerator temperature rises because the cooling cycle is not being sustained

Equipment Compatibility:

The Packard EMI30ER1 Embraco 1/12 Horsepower Compressor R12 is intended for refrigeration systems requiring the specified 1/12 horsepower compressor and R12 refrigerant application. Before purchase, match the required refrigerant and compressor power specification with SKU EMI30ER1 to verify that the compressor corresponds to the intended refrigerator application.

Technical Specifications:

Brand: Packard / Embraco
SKU: EMI30ER1
Product Type: Compressor
Horsepower: 1/12 HP
Refrigerant: R12
Write Your Own Review
You're reviewing:Packard EMI30ER1 Embraco 1/12 Horsepower Compressor R12
Your Rating
Customer Questions
Can the EMI30ER1 be used in a refrigerator that requires R12 refrigerant?

Yes. The EMI30ER1 is specified for R12 refrigerant applications, so the refrigerator's required refrigerant should correspond to R12.

Is the 1/12 horsepower rating important when selecting the EMI30ER1?

Yes. The 1/12 horsepower rating identifies the compressor's specified power class and should correspond to the refrigeration system's requirements.

Can I select the EMI30ER1 based only on the horsepower rating?

No. The R12 refrigerant specification also needs to correspond to the refrigerator's refrigeration system.

What happens when the compressor cannot maintain refrigerant compression?

The refrigeration cycle can be interrupted because the refrigerant is no longer being compressed and circulated through the required stages of the cooling circuit.

What specifications should I compare before purchasing the EMI30ER1?

Compare the refrigerator's required refrigerant and compressor horsepower with the R12 and 1/12 HP specifications of the EMI30ER1 before purchase.